
Add to Cart
SPECIFICATIONS
Manufacturer :Teledyne Analytical Instruments
Product No. : A-5 Intermittent or continuous monitoring of percent Oxygen (O2) in gas mixtures containing 0-100% Carbon Dioxide (CO2). 90% response time is 45 seconds
Introduction:
Teledyne’s patented Micro-fuel Cell (MFC) is a unique,electrochemical transducer that provides versatile oxygen sensing capability by combining the following features.
Specificity to Oxygen
Completely maintenance free
Absolute zero - requires no “zero” gases
Long life
Long term stability, two to four weeks (and longer) calibration interval
Unaffected by variations in sample flow rate
Unaffected by shock, vibration or position
Theory of Operation
Oxygen in the gas space surrounding the cell diffuses through a Teflon membrane and is reduced on the surface of the cathode. A corresponding oxidation occurs at the anode internally and an electrical current is produced that is proportional to the concentration of oxygen.
Cathodic reaction: 4e- + 2 H2O + O2 arrow 4 OH
Anodic reaction: 2 OH- = Pb arrow PbO + H2O + 2e
Overall reaction: 2 Pb + O2 arrow 2 PbO
The transducer operates thusly as a fuel cell, and its output is limited only by the rate at which oxygen enters the cell and the amount of anode material stored within. This output is insufficient for the cell to be utilized as a power source, which is the purpose of most fuel cells. However, the cell does provide sufficient output to drive meters directly or, after amplification, will provide outputs capable of performing more complicated functions
Physical Characteristics
The MFC is a sealed, disposable oxygen transducer that measures 1.25 inches in diameter and is .75 inches thick. It has a relatively large sensing area (0.7 inches diameter) that produces a high level output signal that does not require amplification to drive analog display devices.
The large sensing area also reduces the reading errors associated with vapor condensation from sample streams that normally cause small sensing area transducers to read low or even zero.
The rear of the MFC is covered by a contact plate that consists of two concentric foils. These foils mate to spring loaded contacts in the various probe assemblies and sample manifolds in which the cells are housed.
Related Products:
Sensors for Oxygen Analyzers
Class | Part Number | Application | Warranty |
A-2C | C06689-A2C | Used for trace Oxygen (O2) measurements in Carbon Dioxide (CO2) containing backgrounds (0.1-100% CO2). CO2 must be present | 6 months |
A-2CXL | B74033-A2CXL | Specially qualified A2C sensor to operate in XL model analyzers. Low range limit is 0-1 ppm | 6 months |
A-5 | C06689-A5 | Intermittent or continuous monitoring of percent Oxygen (O2) in gas mixtures containing 0-100% Carbon Dioxide (CO2). 90% response time is 45 seconds | 6 months |
B-1C | C06689-B1C | General purpose percent oxygen analysis where fast response is desired (90% in less than 7 seconds) | 6 months |
B-2C | C06689-B2C | General purpose trace Oxygen (O2) analysis for use in inert gas and hydrocarbon streams. Low range limit is 0-10 ppm. | 6 months |
B-2CXL | C06689-B2CXL | Specially qualified B-2C sensor to operate in XL model analyzers. Low range limit is 0-1 ppm. | 6 months |
B-3 | C06689-B3 | Percent Oxygen (O2) analysis, best compromise between long life and fast response | 12 months |
E-2 | C57283-E2 | Long life cell for use is the model 3290 (for use in unattended air liquefaction nitrogen skids) | 24 months |
InstaTrace | B71875 | Special patented construction provides rapid recovery, during initial cell installation, to low ppm levels by reducing the recovery period from several hours to just minutes. | 6 months |
InstaTrace-CO2 | B73016 | Special patented construction provides rapid recovery, during initial cell installation, to low ppm levels by reducing the recovery period from several hours to just minutes. | 6 months |
InstaTrace-XL | B73592 | Special patented construction provides rapid recovery, during initial cell installation, to low ppm levels by reducing the recovery period from several hours to just minutes. | 6 months |
L-2C | C06689-L2C | Used for general purpose trace oxygen analysis in the 3000T analyzer series | 12 months |
FAQ of Achievers
Q:Are the Products Genuine OEM Units?
A: These items have been certified by Achievers Automation Limited to be genuine OEM Units obtained through OEM or independent third-party channels.
Q:What is the warranty of goods?
A: One-year Warranty.